# Lithium Battery Storage Charge Level

Learn the right storage charge level for lithium and LiPo battery packs, why full charge sits poorly, and how to check and adjust packs before long-term storage.

A lithium battery keeps its health in storage when it holds a partial charge instead of a full one. The storage charge level for lithium-ion packs and LiPo packs sits around 40 to 60 percent of capacity. Charging a pack to full and leaving it on the shelf causes capacity loss, so plan a storage state of charge before the pack goes into long-term storage. 

- Store lithium packs at a partial charge, around 40 to 60 percent of capacity, not at full charge.
- A full charge left in storage speeds capacity loss, while a partial charge protects the cells.
- LiPo packs use a storage charge setting on the charger, often shown as a storage voltage per cell.
- Cordless tool batteries benefit from the same partial charge rule during long-term storage.
- Check the state of charge with a voltmeter or the charger display before and during storage.
 

## What a storage charge level means 

A storage charge level is the state of charge a lithium pack holds while it sits unused. The state of charge is the amount of energy left in the cells compared with a full pack. Lithium packs age faster at a full charge and at a very low charge, so the middle range keeps the cells calm. 

The storage state of charge for lithium-ion cells sits around 40 to 60 percent of capacity. That range leaves room for the pack to self-discharge slowly without dropping into a harmful low voltage. A pack held at partial charge loses capacity more slowly than a pack held at full charge. 

Storage charge is a working setting, not a permanent state. You set it when the pack goes into long-term storage and bring the pack back to full only when a job needs it. A pack that cycles between jobs can stay at partial charge without harm. 

## Why full charge hurts a stored pack 

A lithium battery stored fully charged sits at high voltage for the whole storage period. High voltage stresses the cell chemistry and drives capacity loss during storage. The longer a full pack sits, the more capacity it gives up. 

A full charge is the right level for a pack that goes straight into a tool or a model. The problem starts when the pack stays full with no load on it for weeks. A cordless tool battery left on the charger for months falls into that trap. 

The reverse mistake is just as real, because a pack drained flat and stored that way can fall below its safe voltage. A pack that drops too low may refuse to charge again. The partial charge range avoids both ends of the scale. 

## Setting a LiPo pack to storage charge 

A LiPo storage charge is the partial charge level a lithium polymer pack should hold between uses. LiPo packs power model aircraft, cars and drones, and they tolerate full charge poorly in storage. The charger handles the level through a storage charge program. 

The storage setting brings a pack down from full or up from low to the target level. A charger set for storage reads the cell count and stops at the storage voltage per cell. Check the pack voltage on the display once the program finishes. 

LiPo storage voltage is the per-cell figure the charger targets, and the pack label states the cell count. Follow the charger and pack instructions for that figure, because it depends on the cell chemistry. Never leave a charging LiPo pack unattended, and charge it on a fire-resistant surface. 

## Storage charge for cordless tool packs 

A cordless tool battery pack deserves the same partial charge treatment during long-term storage. Tool packs hold lithium cells in a hard case, and the state of charge still drives capacity loss. A pack parked at full charge through the off-season gives up capacity. 

Run the tool until the pack reaches a partial charge, or use a charger with a storage setting. Many tool chargers lack that program, so a voltage check with a meter gives the reading instead. Compare the reading with the pack label to judge the state of charge. 

Keep stored packs in a dry place within the temperature range the maker states. Heat speeds capacity loss, so a shelf away from a window or a heater serves the pack better. Bring the pack to full charge only when the next job starts. 

## Checking the state of charge before storage 

A voltage reading is the simple way to check the state of charge of a lithium pack. The charger display or a voltmeter shows the pack voltage, and the pack label gives the full voltage. A reading near the middle of the range points to a partial charge. 

Resting voltage is the figure to read, because a pack fresh off a load shows a misleading number. Let the pack sit before you take the reading. A pack that reads low after rest needs a partial charge before storage. 

Write the storage date and the voltage on a label taped to the pack. A written note helps you spot a pack that drifts low over a long storage period. Check stored packs at intervals and top up a pack that falls toward the low end. 

## Long-term storage and capacity loss 

Capacity loss during storage depends on the charge level, the temperature and the time in storage. A pack at partial charge in a cool, dry place keeps more of its capacity. A full pack in a warm place loses the most. 

Long-term battery storage calls for a plan, not a shelf and a hope. Set the pack to the partial range, label it and store it where the temperature stays steady. Bring the pack out and check the level at set intervals. 

A pack that sits for a full season may drift below the partial range. Top it back to the storage level rather than to full charge. The pack then returns to storage in the state it needs. 

- Set the pack to a partial charge around 40 to 60 percent.
- Label the pack with the date and the voltage reading.
- Store the pack in a dry place with a steady temperature.
- Check the voltage at intervals during the storage period.
- Top up a pack that drifts toward the low end of the range.
- Charge to full only when the next job needs the pack.
 

## Full charge vs partial charge in daily use 

A full charge has a place in a working rotation, because a pack at full delivers the longest run time. A partial charge suits a pack that waits between jobs. Match the charge level to the gap before the next use. 

A pack that returns to the charger after every job can stay at partial charge between those jobs. Charge to full on the day of the job and use the pack down. A pack left full for weeks is the case the storage rule targets. 

The choice depends on how long the pack sits, not on a fixed rule for every pack. A short gap tolerates a full charge, and a long gap calls for the partial range. The pack label and the charger instructions give the figures for your cells. 

## Questions About Lithium Storage Charge 

### Should lithium batteries be stored fully charged? 

No, a lithium battery should not be stored fully charged. A full charge held through storage drives capacity loss, so set the pack to a partial charge around 40 to 60 percent instead. Charge to full only when the next job needs the pack. 

### What is storage charge for LiPo batteries? 

Storage charge for a LiPo battery is the partial charge level the pack holds between uses. The charger storage program brings the pack to a storage voltage per cell set for that chemistry. Follow the pack label and charger instructions for the figure. 

### What charge level should a battery pack hold for storage? 

A battery pack should hold a partial charge around 40 to 60 percent of capacity for storage. That range keeps the cells away from the stress of full voltage and the risk of a very low charge. Check the level with a voltmeter or the charger display. 

### Is it best to store batteries fully charged? 

No, storing batteries fully charged is not the right approach for lithium packs. Full voltage during storage speeds capacity loss, while a partial charge protects the cells. Keep the full charge for the day of the job. 

### Does a cordless tool battery need a storage charge level? 

Yes, a cordless tool battery benefits from a partial charge during long-term storage. Run the tool down or use a charger storage setting, then keep the pack in a dry place within the maker's temperature range. Charge it to full when the next job begins.